ADC step size and dynamic range

Smallest voltage step an analogue-to-digital converter can resolve.

Ref
CMP-05
Rev
v1
Field
Computer
Result
ΔV [mV]

ΔV the size of one step (the LSB), Vspan the full input span and n the number of bits. An ideal uniform n-bit converter splits the span into 2ⁿ bins. The sampling rate must also satisfy fs > 2 fmax.

An n-bit converter can only report 2ⁿ different levels. The step size is the voltage span divided by that number, which sets the smallest change it can see.

Calculator

Solve for
mV
V
0.520
bits
824
  • Number of levels 2ⁿ4,096
  • Ideal dynamic range 6.02n + 1.7674 dB

What drives the result

Each variable is moved across its typical range while the others stay at the values above. The longest bar is the key driver.

Step size (mV) current value 0.8057 mV
nNumber of bitsKey driver
1.97e-412.9
VspanInput span
0.1224.88
  • Every extra bit doubles the number of levels and adds about 6 dB of ideal dynamic range.
  • Real converters give fewer “effective” bits than their nominal count because of noise and distortion.
  • Choose the input span to match the sensor’s output so the signal uses most of the range.
Chart data as tables

Ranked variables

VariableTypical rangeLowest resultHighest resultSwing (mV)Local stepChange in result
n Number of bits8 to 24 bits1.967e-412.8912.89+10%−56.5 %
Vspan Input span0.5 to 20 V0.12214.8834.761+10%+10 %

Sweep of Number of bits

Number of bits (bits)Step size (mV)
812.89
103.223
120.8057
140.2014
160.05035
180.01259
200.003147
227.868e-4
241.967e-4

Sweep one variable

Step size (mV)Hover, touch, or use the arrow keys on the chart
024681012 812162024 Number of bits (bits) now 0.8057

Variables and how each one contributes

ΔV

Step size

Result · mV

What the equation gives you. Everything else feeds it.

Vspan

Input span

V · typical 0.5 to 20

Full input voltage range of the converter. Directly proportional.

n

Number of bits

bits · typical 8 to 24

Resolution of the converter. Each extra bit halves the step size.

Worked example with the values above

  1. Levels: 212 = 4,096.
  2. Step = 3.3 V / 4,096 = 8.057×10−4 V.
  3. In millivolts, 0.8057 mV per step.

Assumptions and limits

  • Ideal uniform converter.
  • Signal fills the input span.
  • Sampling above twice the highest signal frequency, with an anti-alias filter.

Common mistakes

  • Assuming noise-free bits: effective bits are lower.
  • Using 2ⁿ − 1 steps in some definitions; check the datasheet.
  • Undersampling and aliasing.

Statistics and uncertainty

The quantisation error is uniform within ±½ step, giving an RMS error of ΔV/√12, about 0.29 LSB. Real converters add noise, offset and gain error of a few LSB, usually specified as ENOB.

Where it is used

  • Radar, sonar and sensor digitisation.
  • Data acquisition and telemetry.
  • Choosing a converter for a measurement system.

Maths you need

  • Powers of two: 2ⁿ levels
  • Sampling: Nyquist criterion