Thermal diffusivity and Fourier number
Dimensionless time for heat to diffuse through a body.
- Ref
- HTR-05
- Rev
- v1
- Field
- Heat Transfer
- Result
- Fo
The Fourier number measures diffusion time relative to the length scale Lc. Values around 0.2 or more mean heat has penetrated the whole body.
Fo says how many times heat has had time to cross the body: small values mean the inside has not yet felt the surface temperature change.
Calculator
- Thermal diffusivity α13.35 10⁻⁶ m²/s
- Diffusion time Lc²/α187.2 s
What drives the result
Each variable is moved across its typical range while the others stay at the values above. The longest bar is the key driver.
- Steel has α about 13×10⁻⁶ m²/s; heat takes about three minutes to cross a 5 cm length scale.
- Doubling the length scale needs four times the time to reach the same Fo.
Chart data as tables
Ranked variables
| Variable | Typical range | Lowest result | Highest result | Swing () | Local step | Change in result |
|---|---|---|---|---|---|---|
| Lc Length scale | 0.001 to 1 m | 8.013e-4 | 801.3 | 801.3 | +10% | −17.4 % |
| ρ Density | 100 to 20,000 kg/m³ | 0.125 | 25 | 24.87 | +10% | −9.09 % |
| t Time | 1 to 3,600 s | 0.005342 | 19.23 | 19.23 | +10% | +10 % |
| k Conductivity | 0.05 to 400 W/(m·K) | 3.205e-4 | 2.564 | 2.564 | +10% | +10 % |
| cp Specific heat | 100 to 5,000 J/(kg·K) | 0.03077 | 1.538 | 1.508 | +10% | −9.09 % |
Sweep of Length scale
| Length scale (m) | Fourier number |
|---|---|
| 0.001 | 801.3 |
| 0.002371 | 142.5 |
| 0.005623 | 25.34 |
| 0.01334 | 4.506 |
| 0.03162 | 0.8013 |
| 0.07499 | 0.1425 |
| 0.1778 | 0.02534 |
| 0.4217 | 0.004506 |
| 1 | 8.013e-4 |
Sweep one variable
Variables and how each one contributes
Fourier number
What the equation gives you. Everything else feeds it.
Conductivity
Thermal conductivity. Raises Fo.
Density
Density. Lowers Fo.
Specific heat
Specific heat. Lowers Fo.
Time
Elapsed time. Raises Fo.
Length scale
Characteristic length (half-thickness). Squared: the strongest driver.
Worked example with the values above
- α = k/(ρcp) = 50 / (7,800 × 480) = 1.335×10−5 m²/s.
- α t = 8.013×10−4 m²; Lc² = 0.0025 m².
- Fo = 0.3205.
Assumptions and limits
- Constant properties.
- A representative characteristic length.
Common mistakes
- Using the full thickness where half-thickness is needed.
- Using minutes for time.
Statistics and uncertainty
Properties vary by 5–10% with temperature, but the length scale enters squared and often dominates.
Where it is used
- Transient heating and cooling estimates.
- Choosing between lumped and detailed models.
Maths you need
- Thermal conductivity: k
- Specific heat: cp