Library / Fluid Mechanics / FLU-06
Fluid Mechanics
Pump shaft power
Power a pump shaft needs to deliver a flow at a given head.
- Ref
- FLU-06
- Rev
- v1
- Field
- Fluid Mechanics
- Result
- Pshaft [kW]
Use actual volumetric flow Q in m³/s, pump head hp in metres and efficiency as a fraction. Motor electrical input also depends on motor efficiency. Q is entered in L/s.
Lifting a flow of liquid to a head needs power set by the flow, the head and the fluid weight, and the pump wastes some of it as heat.
Calculator
- Hydraulic power5.884 kW
- Heat dumped into the fluid2.522 kW
What drives the result
Each variable is moved across its typical range while the others stay at the values above. The longest bar is the key driver.
- Power rises with flow × head, and a pump at 70% efficiency wastes 30% as heat.
- Motor selection should add a margin on the shaft power and account for motor efficiency.
Chart data as tables
Ranked variables
| Variable | Typical range | Lowest result | Highest result | Swing (kW) | Local step | Change in result |
|---|---|---|---|---|---|---|
| Q Flow rate | 0.1 to 1,000 L/s | 0.04203 | 420.3 | 420.2 | +10% | +10 % |
| hp Pump head | 1 to 300 m | 0.2802 | 84.06 | 83.78 | +10% | +10 % |
| ηp Pump efficiency | 0.2 to 0.95 | 6.194 | 29.42 | 23.23 | +undefined% | — |
| ρ Density | 600 to 1,500 kg/m³ | 5.043 | 12.61 | 7.565 | +10% | +10 % |
Sweep of Flow rate
| Flow rate (L/s) | Shaft power (kW) |
|---|---|
| 0.1 | 0.04203 |
| 0.3162 | 0.1329 |
| 1 | 0.4203 |
| 3.162 | 1.329 |
| 10 | 4.203 |
| 31.62 | 13.29 |
| 100 | 42.03 |
| 316.2 | 132.9 |
| 1,000 | 420.3 |
Sweep one variable
Variables and how each one contributes
Shaft power
What the equation gives you. Everything else feeds it.
Density
Fluid density. Directly proportional.
Flow rate
Volumetric flow. Directly proportional.
Pump head
Pump head. Directly proportional.
Pump efficiency
Pump efficiency as a fraction. Inversely proportional.
Worked example with the values above
- Flow: 20 L/s = 0.02 m³/s.
- Hydraulic power: ρgQhp = 1,000 × 9.807 × 0.02 × 30 = 5,884 W.
- Pshaft = 5.884 / 0.7 = 8.406 kW.
Assumptions and limits
- Steady operation at the duty point.
- Incompressible fluid.
Common mistakes
- Using L/s in an equation that needs m³/s.
- Using hydraulic power as the motor rating.
Statistics and uncertainty
Efficiency is read from the pump curve with about ±3–5% accuracy, which adds directly to the power estimate.
Where it is used
- Sizing pump motors.
- Energy-use estimates for cooling-water circuits.
Maths you need
- Pump head: m
- Power: W